Comtech EF Data UT-4505 Installation And Operation Manual page 85

Ut-4500 series
Hide thumbs Also See for UT-4505:
Table of Contents

Advertisement

UT4500 Series Up Converter
Remote Control
5.6.2.2 A
TTENUATOR
The default is 10 dB.
Command
Set Attenuator:
Confirmation:
Retrieve Attenuator:
Confirmation:
Note: yy.yy = 0.0 to 25.00 dB in 0.25 steps.
5.6.2.3 C
S
OLD
TART
The cold start function, if enabled, mutes the output signal for a predetermined time
following Power-Up to ensure a stable reference oscillator (15 minutes). The default is
OFF. This command is disabled in redundant systems (i.e. COMMAND NOT
AVAILABLE).
Command
Set Cold Start:
Confirmation:
Retrieve Status:
Confirmation:
5.6.2.4 M
UTE
The default is ON.
Command
Mute Output:
Confirmation:
Retrieve Mute
Status:
Confirmation:
Details
<DEV/ATT_ yy.yy'cr'
>DEV/ATT_yy.yy'cr'lf']
<DEV/ATT_'cr'
>DEV/ATT_ yy.yy'cr''lf']
Details
<DEV/CLD_xxx'cr'
>DEV/CLD_xxx'cr''lf']
<DEV/CLD_'cr'
>DEV/CLD_xxx'cr''lf']
Details
<DEV/MUT_xxx'cr'
>DEV/MUT_xxx'cr''lf']
<DEV/MUT_'cr'
>DEV/MUT_yyy'cr''lf']
yyy = ON/OFF/COLD
67
xxx = ON or OFF
xxx = ON or OFF
MN/UT4500.IOM
Revision 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents