General Specifications
Table 2.2. General Specifications
Condition
Environment
Operating temperature
Storage temperature
Operating humidity
Floating dust
Corrosive gas
Noise
Line noise
resistance
Electrostatic
withstanding
voltages
Vibration
Sweep
resistance
durability
Fixed-vibration
durability
Shock resistance
Structure
Major dimensions (mm)
Panel cut dimensions (mm)
Mountable panel thickness
Weight
Ingress protection
User's Manual
IPC-DT/M20V(PC)T
0 - 50ºC (0 - 40ºC when using an IPC-ACAP12-01 (AC switching adapter))
-10 - 60ºC
10 - 90%RH
(20 - 80% when using an IPC-ACAP12-01 (AC switching adapter))
(No condensation allowed)
Normal
None
AC line: 2 kV, Signal line: 1 kV
(IEC1000-4-4Level3, EN61000-4-4Level3)
(HOST: IPC-BX/M600(PCW) Power supply: IPC-POA200/12-01)
Contact: 4 kV(IEC1000-4-2Level2, EN61000-4-2Level2)
Airborne: 8 kV(IEC1000-4-2Level3, EN61000-4-2Level3)
(HOST: IPC-BX/M600(PCW) Power supply: IPC-POA200/12-01)
10 - 50 Hz/Single-side amplitude or 0.15 mm
50 - 500 Hz/2.0 G in the X/Y/Z directions for 23 minutes each
(Conforming to JIS C0040 and IEC68-2-6)
16.7 Hz/2 G in the X/Y/Z directions for 30 minutes each
(Conforming to JIS C0040 and IEC68-2-6)
10 G in the X/Y/Z directions for 11 ms; Half-sine wave
(Conforming to JIS C0041 and IEC68-2-27)
317(W) x 44(D) x 277(H)
292±0.5(W) x 252±0.5(H)
10 mm or less
3.5kg
Front part conforming to IP65
Specification
IPC-DT/L20S(PC)T
370(W) x 48(D) x 307(H)
344±0.5(W) x 281±0.5(H)
(12 stud holes are required
on the periphery.)
4.4kg
2. Specifications
IPC-DT/H20X(PC)T
428(W) x 48(D) x 336(H)
398±0.5(W) x 306±0.5(H)
(12 stud holes are required
on the periphery.)
5.5kg
9