Cleaning the transport

5-12
Over time, the transport will become dirty and may feed documents
erratically or skew the documents as they enter the scanner. To prevent
erratic feeding, clean the transport every 50,000 pages or as needed.
NOTE: It is recommended that you clean the imaging guides again after
cleaning the transport with a transport cleaning sheet.
1. Establish communication between the scanner and the Ngenuity
Operator Utility.
2. Verify that one of the Custom Functions is set to Feed Test Batch.
3. Press F1 or F2 key depending on which key is assigned to "Feed
Test Batch". This will start the scanner transport. By default, the F1
key is assigned the Feed Test Batch function.
4. Feed the transport cleaning sheet in landscape orientation into the
scanner transport.
5. Observe the cleaning sheet, and run it through the transport again,
changing its position slightly each time, until the tires leave no dark
streaks.
6. Turn the transport cleaning sheet over and run it through the
scanner transport two times.
7. Press and hold the Pause/Stop button (2-3 seconds) until the
scanner stops running.
8. Press the Clear/Restart button.
9. When finished, discard the transport cleaning sheet. After running
the cleaning sheet, inspect the imaging guides. It may be necessary
to clean off any residue from the cleaning sheet that may be on the
imaging guides.