12. Exit sensor: The exit sensor is located on the transport toward the
back of the scanner. Clean the exit sensor by placing the brush end
of the blower brush into the exit sensor area and squeeze the
blower brush several times.
Exit sensor
13. When all sensors are clean, close the transport cover and reset the
maintenance reminder by clicking on the Clean Optics hyperlink on
the Maintenance monitor.
14. Click Reset on the dialog box to confirm the optics have been
cleaned. The reminder will be reset for the next required
maintenance session.