SIS
Programming and Control, cont'd

Ethernet (LAN) Port

The rear panel LAN connector on the switcher can be connected to an Ethernet
LAN or WAN, making makes SIS control of the switcher possible. Communication
between the switcher and the controlling device is via Telnet (a TCP socket using
port 23). The Telnet port can be changed, if necessary, via SIS. The SIS commands
and behavior of the product are identical to the commands and behavior the
product exhibits when you are communicating with it via a serial port.

Ethernet connection

The Ethernet cable can be terminated as a straight-through cable or a crossover
cable and must be properly terminated for your application (figure 4-3).
12345678
Insert Twisted
Pair Wires
Connector
Figure 4-3 — RJ-45 Ethernet connector pin assignments

Default IP parameters

To access the switcher via the Ethernet port, you need the Extron IP address and
may need the subnet mask and the gateway address. If the IP address has been
changed to an address comprised of words and characters, you can determine the
actual numeric IP address using the ping (ICMP) utility (see appendix A, "Ethernet
Connection", for more details). If the addresses have not been changed, the factory-
specified defaults are:
• IP address
• Gateway address
• Subnet mask
• DHCP
4-4
MPX Plus 866 A Media Presentation Matrix Switcher • SIS Programming and Control
Crossover cable — Direct connection between the computer and the
MPX switcher
Patch (straight) cable — Connection of the MPX switcher to an Ethernet LAN
Crossover Cable
Pins:
End 1
Pin
Wire color
1
White-green
2
Green
3
White-orange
4
Blue
5
White-blue
6
Orange
7
White-brown
8
Brown
T568A
RJ-45
A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.
192.168.254.254
0.0.0.0
255.255.0.0
off
Straight-through Cable
End 2
End 1
Wire color
Pin
Wire color
White-orange
1
White-orange
Orange
2
Orange
White-green
3
White-green
Blue
4
Blue
White-blue
5
White-blue
Green
6
Green
White-brown
7
White-brown
Brown
8
Brown
T568B
T568B
A cable wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.
End 2
Wire color
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
T568B

Advertisement

Table of Contents
loading