D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specified. Framing or finishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Mantels (Combustible/Non-Combustible)
3/8 in. (10 mm)
Thick Wall
Sheathing
12 in. (300 mm)
14-1/8 in
(360 mm)
Figure 5.3 Clearances To Combustible Mantels Or Other
Combustibles Above Appliance
Note: For non-combustible fireplace finish material (marble,
stone, etc) specifications refer to Section 13.
Mantel Leg (Combustible/Non-Combustible)
TOP VIEW
3-1/8 in.
(80 mm)
MINIMUM
Figure 5.4 Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
MAX.
MEASUREMENT
FROM TOP OF
FIREPLACE
MIN.
OPENING
UNLIMITED
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12
Front Side Finishing Detail
1-1/2 in. (37 mm)
Figure 5.5 Front Side Finishing Detail
3-1/2 in.
(89 mm)
1 in.
(25 mm)
1 in. (25 mm)
Figure 5.6 Non-Combustible Zone
AIR SPACE
Note: AIR SPACE denoted in Figure 5.6 is defined by the
nailing tabs and top metal standoffs.
1-1/8 in. (30 mm)
FRAMING
3/8 in (10 mm) BUILDING MATERIAL
3/8 in. (10 mm) THICK
WALL SHEATHING
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE