Listing and Code Approvals
A. Appliance Certification
MODELS: XLR-PLUS-N-AU, XLR-PLUS-PB-AU
LABORATORY: SAI Global
TYPE: Gas Space Heating Appliance
STANDARD: AS4553:2008
The Heat & Glo gas appliances discussed in this Installer's
Guide have been tested to certification standards and listed
by the applicable laboratories.
This appliance must be installed in accordance with the
rules in force.
NOX Class 5 for G20, NOX Class 5 for G31
B. Gas Pressure Requirements
Pressure requirements for XLR-PLUS fireplaces are
shown in table below.
Two taps are provided on the right hand side of the gas
control for a test gauge connection to measure the inlet
and outlet pressures.
The fireplace and its individual shut-off valve must be dis-
connected from the gas supply piping system during any
pressure testing of the system at test pressures in excess
of 3.4 kPa.
If the fireplace must be isolated from the gas supply pip-
ing system by closing an individual shut-off valve, it must
be of the handle-less type.
Inlet Gas Pressure
Outlet (Manifold) Gas Pressure
Gas Rate
Maximum Gas Consumption
Burner Injector
Pilot Injector
Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum
inlet pressure of 3.40 kPa. For pressures over 3.40 kPa, an in line pressure regulator must be installed
upstream from the gas control valve.
Natural Gas
1.13 - 3.40 kPa
.80 - .95 kPa
.405
/
m3
26 MJ/h
DMS 42 (2.350 mm)
Ø .023 (.584 mm)
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12
C. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 ft. (610 m) elevation:
Reduce input rate 4% for each 1000 ft. (305 m) above
2000 ft. (610 m).
D. Non-Combustible Materials Specification
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC (1382 °F) and UL763
shall be considered non-combustible materials.
E. Combustible Materials Specification
Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
and burn, whether flame proofed or not, or plastered or
unplastered shall be considered combustible materials.
F. Electrical Codes
All electrical safety testing has been done following the EN
60335-2-102 standard. Local codes apply.
Propane
2.75 - 3.40 kPa
2.36 - 2.61 kPa
.134
h
26 MJ/h
DMS .057 (1.450 mm)
Ø .014 (.356 mm)
Butane
2.75 - 3.40 kPa
2.36 - 2.61 kPa
/
.111
m3
h
22 MJ/h
DMS 55 (1.325)
Ø .010 (.254 mm)
/
m3
h
9