G. Gas Valve Replacement
Once the valve assembly has been removed, the gas
valve, pilot assembly, orifice flex tube, and flex ball valve
can be replaced.
Figure 16.8
1. Place the valve assembly on a clean, stable surface to
service or replace any components.
2. Disconnect the orange and green wires from the
valve.
3. Removed the Pilot fitting from the valve assembly
4. Disconnect the orifice gas flex and gas ball valve flex
from the (2) flare fittings.
5. Unscrew (2) screws located under the pressure taps
to remove the gas valve from the valve bracket.
VALVE
BRACKET
GAS INTLET FLEX
FLARE FITTING
Figure 16.9
GAS VALVE
ORFICE FLEX
PILOT FITTING
PILOT FITTING
Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12
H. Pilot Assembly Replacement
Figure 16.10
1. Disconnect the orange and white wires from the con-
trol module.
2. Remove the pilot fitting from the valve assembly.
3. Remove two screws that secure pilot assembly to the
pilot bracket.
PILOT
BRACKET