Timing

This determines how timing-related settings—Tempo, Swing, Gate, and Time Division—
affect the Sequences:
Locked: The next Sequence will use the same timing settings as the current Sequence.
If you choose this setting before starting playback, the first Sequence you play
determines the timing settings.
If you choose this setting after starting playback, the current Sequence determines the
timing settings.
Important: If you trigger a Sequence whose timing settings are temporarily changed due
to the Locked feature and then save that Sequence, it will be saved with the new timing
settings.
NewSeq: The next Sequence will use the timing settings that you saved with the
Sequence.
Important: If you do not save a Sequence you created or edited and then trigger a different
Sequence in Next Sequence Mode, your unsaved changes will be lost.

Mode

This setting determines what happens when the Sequence reaches its end:
Loop: A playing Sequence will repeat until you select a new one.
One-Shot: A playing Sequence will play only once and then stop when it reaches its end.
SEQUENCER
NEXT SEQUENCE MODE
Press a pad to play
that sequence next
CURR:Sequence01
WHEN:
TIMING:
EndSeq
Locked
76
NEXT:Sequence02
MODE:
Loop
EXIT