TO CORD ASSEMBLY
120VAC
FLAME
MODULATION
ORANGE
GREEN
(PILOT)
(MAIN)
Figure 10.2 IPI Wiring Diagram

PILOT ASSEMBLY

THERMOCOUPLE
VALVE
Figure 10.3 Standing Pilot Ignition Wiring Diagram
Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP • 2206-900 Rev. K • 6/11
INTERMITTENT
PILOT IGNITOR
MODULE
ORG
WHT
RED
BLK
BROWN
GROUND
THERMOPILE
PIEZO
RED
WHT
RC100
RC200
(OPTIONAL WALL CONTROLS)
AUX300 MODULE
FAN
AUX1 AUX2
BATTERY PACK
6V DC
RED
BLK
WALL SWITCH
OR REMOTE
INSTALL
ROCKER
SWITCH
RC300
AUX2 NOT USED FOR INSERT MODELS.
PROTECTIVE COVER INCLUDED
TO CORD
ASSEMBLY