Heat & Glo SL-550TRSI-AUE Installation And Operation Instructions Manual
Heat & Glo SL-550TRSI-AUE Installation And Operation Instructions Manual

Heat & Glo SL-550TRSI-AUE Installation And Operation Instructions Manual

Hearth and home technologies heater manual sl-550trsi-aue
Hide thumbs Also See for SL-550TRSI-AUE:

Advertisement

INSTALLATION AND OPERATION
INSTRUCTIONS
MODEL: SL-550TRSI-AUE
AUSTRALIAN GAS ASSOCIATION APPROVED
Approval Number 5666
THIS MANUAL MUST BE USED FOR INSTALLATION AND RETAINED
BY HOMEOWNER FOR OPERATION AND MAINTENANCE.
HEAT & GLO, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044 USA • 1-888-427-3973
THIS PRODUCT MAY BE COVERED BY ONE OR MORE OF THE FOLLOWING PATENTS:
(United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407,
5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474,
6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada) 1297749,
2195264, 2225408; (Australia) 543790;586383; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SL-550TRSI-AUE

  • Page 1 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408; (Australia) 543790;586383; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06...
  • Page 2 Heat & Glo, a brand of Hearth & Home Technologies, Inc. 20802 Kensington Blvd., Lakeville, MN 55044, USA Copyright 2006 • Printed in U.S.A. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 AND USING THIS APPLIANCE. before starting installation and follow these instructions carefully during installation to ensure maximum benefit and safety.
  • Page 3: Table Of Contents

    3.3 Parts Replacement ... 33 3.4 Adjustments and Replacement Parts ... 33 3.5 Maintenance Tasks ... 34 3.6 Troubleshooting ... 35 4.0 Replacement Parts ... 37 Limited Warranty ... 39 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 TABLE OF CONTENTS...
  • Page 4 (924mm) (813mm) 2-1/8 in. (55mm) GAS LINE ACCESS 6 in. (153mm) Figure 1. Diagram of SL-550TRSI-AUE Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 25-3/4 in. (653mm) 12-7/8 in. (327mm) 8-3/4 in. (223mm) Ø 6-1/2 in. (165mm) 36 in.
  • Page 5: Installation Instructions

    Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 The heater can be mounted on any of the following sur- face: 1.
  • Page 6: Introduction

    WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL. These units MUST use the flue termination described in the flueing section of the manual. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 The framing headers may rest on the fireplace stand-offs.
  • Page 7 MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES Figure 4 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 M = Gas meter P = Electricity meter or fuse box CLEARANCES 'n' (mm)
  • Page 8: Flue System Approvals And Installation

    SLK-01TRD SLK-991DA Figure 5. Flue Components and Terminations Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 FLUE TERMINATION APPROVALS DVP-TRAP2 & SLK-01TRD HORIZONTAL TERMINATION CAP DVP-TVHW & SLK-991DA VERTICAL TERMINATION CAP configurations using 90° elbows MUST BE strictly adhered to.
  • Page 9 DVP45 217mm 319mm NOTE: PIPES OVERLAP 32mm AT EACH JOINT. Figure 6. DVP-Series Balanced Flue Component Specifications (127mm inner pipe / 203mm outer pipe) Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 152mm DVP6 610mm DVP24 DVP36...
  • Page 10 SL-12/17D NOTE: PIPES OVERLAP 1 3/8 INCHES (35mm) AT EACH JOINT. Figure 7. SL D-Series Balanced Flue Component Specifications (4-inch (102mm) inner pipe / 6 5/8-inch (168mm) outer pipe) Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06...
  • Page 11 FT. (M) 36' MAXIMUM (10.97M) RESTRICTOR PLATE USE SL D-SERIES COMPONENTS ONLY. Figure 8. Figure 9. STRAIGHT OUT HORIZONTAL FLUEING Max. Run 24" (610mm) USE DVP-SERIES COMPONENTS ONLY. Figure 10. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06...
  • Page 12 4' MIN. (1.22M) 12' MAX. (3.66M) V+H =36' MAX. (10.97M) H= 12' MAX. (3.66M) USE DVP-SERIES COMPONENTS ONLY. Figure 12. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 FT. (M) 2' MAX.(0.61M) 4' MAX.(1.22M) 8' MAX.(2.44M) 10' MAX.(3.05M) ELBOW...
  • Page 13 10' MAX. (3.05M) 30' MAX.(9.14M) 10' MAX. (3.05M) USE SL D-SERIES COMPONENTS ONLY. Figure 13. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 FLUEING WITH TWO (2) 90° ELBOWS FT. (M) 1' MIN.(0.30M) 2' MIN.(0.61M) 3' MIN.(0.91M) 4' MIN.(1.22M)
  • Page 14 4´ MIN. (1.22M) V + H + H USE DVP-SERIES COMPONENTS ONLY. Figure 14. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 FLUEING WITH TWO (2) 90° ELBOWS 1´ MAX. (0.30M) 2´ MAX. (0.61M) 3´ MAX. (0.91M) 4´...
  • Page 15 4'MIN.(1.22M) 8' MAX.(2.44M) 5'MIN.(1.52M) 12' MAX.(3.66M) 12' MAX.(3.66M) NOTE: V + V MAX. 33' (10.06M) Figure 15. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 H + H FT. (M) 4' MAX.(1.22M) 6' MAX (1.83M) 8' MAX.(2.44M)
  • Page 16 4´ MIN. (1.22M) 4´ MAX. (1.22M)) V+H+H = 30´MAX.(9.14M) H=4´MAX.(1.22M) H+H Figure 16. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 FLUEING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) 1´ MIN. (0.30M) 1´ MAX. (0.30M) 2´...
  • Page 17 HERE Figure 17. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 WARNING: THE REAR FLUE COL- LAR SEAL CAP MUST REMAIN AT- TACHED TO THE REAR FLUE COL- LARS IF THE FLUE SYSTEM IS AT- TACHED TO THE TOP STARTING COLLARS.
  • Page 18 WARNING: ENSURE THAT THE HEATER GASKET SUPPLIED WITH THE HEATER SEALS BETWEEN THE FIRST FLUE COMPO- NENT AND THE OUTER HEATER WRAP. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 WARNING Fire Risk Exhaust Fumes Risk Impaired Performance of Appliance •...
  • Page 19 PROCEED TO STEP 3 (Install Support Brackets) Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 B. On the TOP of the heater 1. Attaching the First Flue Component to the Start-...
  • Page 20 • The pipe opening of the firestops MUST BE placed towards the bottom of the firestop. • Continue the flue run through the firestop. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 INTERIOR WALL SHIELD Figure 24.
  • Page 21 The other is attached to the termination cap in the same manner (see Figure 28). Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 • The heat shield sections will overlap to match the wall thickness (depth).
  • Page 22: Connecting The Gas Supply

    • Slide the termination cap over the end of the flue pipe and rotate the pipe clockwise 1/4 turn. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 GAS ACCESS Figure 29. Gas Supply Line 1.3 CONNECTING THE GAS SUPPLY The gas is introduced to the appliance on the left hand side.
  • Page 23: Ignition System Wiring

    WARNING Shock Risk • Replace damaged wire with type C rated wire. • Wire must have high temperature insulation. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 FLAME SPARKER/ SENSOR VALVE REMOTE CONTROL ANT. ON/OFF WALL SWITCH...
  • Page 24: Blower Fan

    The access hole for connecting the service wires is found on the right exterior side of the unit. See Figure 32 for wire connection detail. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 • C RATED WIRE.
  • Page 25: Finishing

    (76mm) (51mm) NON-COMBUSTIBLE Figure 33. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 300° F (149°C). MINIMUM SEAL- ANT MATERIAL MUST BE USED. THESE JOINTS ARE NOT REQUIRED TO BE SEALED.
  • Page 26: Installer Testing

    Lighting Instructions. Subsequent lightings of the appliance will not require such purging. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 Follow the Safety Information and Lighting Instructions pages of this manual to light the appliance.
  • Page 27: Log Placement

    Place log #1 onto the log grate so that the notches in the bottom of the log Place log #2 so that its left edge sits against the left front grate corner and Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 TABS...
  • Page 28 Position log #4 between log #1 and the locating tab on the fourth grate bar. Put the forked end of log #5 on the base in front of the grate, towards the Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06...
  • Page 29 Place log #7 on the groove in log #2 with its rear top on log #1 and front top resting on log #5. LOG #8 (SRV347-701): Hook log #8 on the right hand corner grate bar and rest its rear on log #1 as shown. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06...
  • Page 30: Operating Instructions

    WHILE IT IS IN OPERATION. Figure 36. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 • THE DRESS GUARD IS FITTED TO THIS APPLI- ANCE TO REDUCE THE RISK OF FIRE OR INJURY FROM BURNS AND NO PART OF IT SHOULD BE PERMANENTLY REMOVED.
  • Page 31: Safety And Lighting Information

    See installation and operating instructions accompany- ing appliance. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 tact your dealer or a qualified service person to replace the injector or adjust the valve. NOTE: THE TIPS OF THE FLAMES SHOULD NEVER HIT THE TOP OF THE FIREBOX.
  • Page 32: Fan Operation

    Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 When the appliance is put back in service check burner flame patterns with Figure 37.
  • Page 33: Removal Of Covers For Servicing

    RETAINING SCREWS Figure 40. CAUTION: ALL SCREWS WHICH WERE REMOVED MUST BE REPLACED. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 2. PILOT ASSEMBLY/IGNITION SYSTEM • Remove the log set, log grate, metal base pan and burner.
  • Page 34: Maintenance Tasks

    4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and flashing remains intact. Remote controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 Maintenance Tasks...
  • Page 35: Troubleshooting

    Ignitor gap is too large. c. Module is not grounded. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 Possible Causes Press and hold the receiver’s reset button until you hear 2 acoustic signals. After the second longer acoustic signal,...
  • Page 36 Insufficient oxygen and lifts off burner. being supplied. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 Corrective Actions Adjust the log set so that the flame does not impinge on it. Inspect the opening at the base of the burner. It is imperative that NO material be placed in this opening.
  • Page 37: Service Parts

    Service Parts (NG, LP) Exploded Parts Diagram Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 SL-550TRSI-AUE Log set assembly Beginning Manufacturing Date: 6/06 Ending Manufacturing Date: ______...
  • Page 38 Mineral Wool Mesh Assembly Exhaust Resistor Accesssories Wall Switch Kit, Off White Wall Switch Kit, White Conversion Kit NG Conversion Kit LP Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 PARTS PART NUMBER 2098-130 2098-131 582-840 582-057 530-302A...
  • Page 39: Replacement Parts

    HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifications and prices. It also reserves the right to discontinue styles and products. Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 LIMITED 10 YEAR WARRANTY...
  • Page 40 For Service or Replacement Parts Contact: Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. B • 7/06 Melbourne Jetmaster 444 Swan Street Richmond 3121 (03) 9429-5573 Perth Fireplace Corner 277 Lord Street East Perth 6000 (08) 9228-2600 Sydney Jetmaster 10 Martin Avenue...

Table of Contents