ORIGINAL SIZE SENSORS REPLACEMENT

3.6 ORIGINAL SIZE SENSORS REPLACEMENT
[A]
C600R107.WMF
[F]
C600R113.WMF
1. Open the original table.
2. Remove the original guide [A] (3 screws).
3. Replace the following sensors:
Original length sensor 1 [B]
Original length sensor 2 [C]
Original width sensor (1 screw) [D]
Original trailing edge sensor [E]
NOTE: To prevent incorrect size detection, clean the electrode [F] of the original
width sensor using alcohol or a dry cloth. Then apply conductive grease
KS-660 (G0049668).
C600
[D]
[E]
8-14