Blown Fuse Conditions - Ricoh C231 Service Manual

Hide thumbs Also See for C231:
Table of Contents

Advertisement

4.3 FUSE, LED, VR, DIP-SW, AND TP TABLES

4.3.1 BLOWN FUSE CONDITIONS

Main motor board
No.
Rate
Fuse
10.0 A
PSU
No.
Rate
FU700
6.3 A
FU701, 702
5.0 A
FU703, 704
5.0 A
4.3.2 LED'S
MPU
No.
LED101
Not used.
LED102
Monitors the master end sensor. When the sensor detects a master, this LED is
3.5.4)
lit. (
LED103
Monitors the paper feed circuit in the MPU. Usually, this LED is blinking at
intervals of 2 seconds.
LED104
Monitors the CPU operation. Usually, this LED is blinking at intervals of 1
second.
4.3.3 VR'S
MPU
No.
VR101
Not used.
VR102
Adjusts the master end sensor (
PSU
No.
VR1
Adjusts the thermal head voltage. (
VR2
Not used.
C231/C237/C238
The "close the covers" indicator is lit.
The machine does not turn on.
E-13 is displayed, and the output mode in SP mode does
not turn anything on except the main motor.
The "close the covers" indicator is lit.
Function
3.5.4)
Function
4-6
FUSE, LED, VR, DIP-SW, AND TP TABLES
Symptom
Symptom
Function
3.5.3)
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C238C237C248C267Jp1030Jp1230 ... Show all

Table of Contents