1
1.8
Inspection and Adjustment of Hydraulic System
1 Bush Clearance
Check the clearance of the bush and change the ones exceeding the usable limit.
• Check the shaft for oscillating face with the bush for fouling and change accordingly.
• Change the bush if the internal gray fiber layer is worn.
Item
Clearance bet. Lift Shaft and Bush
Clearance bet. Piston Rod and Bush
K&T Saw Shop 606-678-9623 or 606-561-4983
www.mymowerparts.com
Hydraulic System
CAUTION
Reference Value
0.025 to 0.089 {0.0010 to 0.0035}
0.020 to 0.083 {0.0008 to 0.0033}
32
(Unit: mm {in})
Usable Limit
0.30 {0.012}
0.30 {0.012}