B.2
International Electrotechnical Commission (IEC)
Classification of Hazardous Locations,
IEC Methods of
Protection
Protection Concept
Flameproof
Intrinsic Safety
Pressurized
Encapsulation
Increased Safety
Powder Filled
Oil Immersion
Non-sparking
Enclosed Break
Limited Energy
Restricted Breathing
90
The following table summarizes available methods of protection for use
in given locations.
Designation
d
ia
ib
p
m
e
q
o
nA
nC
nA
nR
ST 3000 Release 300 Installation Guide
Permitted Use
Zone 1 & 2
Contains explosion and
quenches flame.
Zone 0, 1 & 2
Limits energy of sparks under
2 faults.
Zone 1 & 2
Limits energy of sparks under
1 fault
Zone 1
Keeps flammable gases out.
Zone 1 & 2
Keeps flammable gases out.
Zone 1 & 2
No arcs, sparks or hot
surface.
Zone 1 & 2
Contains explosion and
quenches flame.
Zone 1 & 2
Keeps flammable gases out.
Zone 2
No arcs, sparks or hot
surfaces under normal
conditions.
Zone 2
Contains explosion and
quenches flame.
Zone 2
Limits energy of sparks and
surface temperature under
normal conditions.
Zone 2
Keeps flammable gases out.
Continued
Principle
Continued on next page
2/05