2–22
Using the Front Panel Keypad
• Parameter Display - A 4-digit, 7-segment display for parameters and function codes.
• Display Units, Hertz/Amperes - One of these LEDs will be ON to indicate the units
associated with the parameter display.
• Power LED - This LED is ON when the power input to the inverter is ON.
• Function Key - This key is used to navigate through the lists of parameters and
functions for setting and monitoring parameter values.
• Up/Down (
parameter and functions shown in the display, and increment/decrement values.
• Store (
value, press the Store key to write the new value to the EEPROM.
Keys, Modes, and Parameters
Purpose of the keypad is to provide a way to change modes and parameters. The term
function applies to both monitoring modes and parameters. These are all accessible
through function codes that are primarily 3-character codes. The various functions are
separated into related groups identifiable by the left-most character, as the table shows.
For example, function "A_04" is the base frequency setting for the motor, typically
50 Hz or 60 Hz. To edit the parameter, the inverter must be in Program Mode (PGM
LED will be ON). You use the front panel keys to first select the function code "A_04."
After displaying the value for "A_04," use the Up/Down (
NOTE: The inverter 7-segment display shows lower case "b" and "d," meaning the same
as the upper case letters "B" and "D" used in this manual (for uniformity "A to F").
The inverter automatically switches into Monitor
Mode when you access "D" Group functions. It
switches into Program Mode when you access
any other group, because they all have editable
parameters. Error codes use the "E" Group, and
appear automatically when a fault event occurs.
Refer to
Conditions" on page 6–5
,
2
) Keys - Use these keys alternately to move up or down the lists of
1
) Key - When the unit is in Program Mode and you have edited a parameter
STR
Function
Type (Category) of Function
Group
"D"
Monitoring functions
"F"
Main profile parameters
"A"
Standard functions
"B"
Fine tuning functions
"C"
Intelligent terminal functions
"H"
Motor constant functions
"E"
Error codes
"Monitoring Trip Events, History, &
for error code details.
PGM LED
Mode to Access
Indicator
Monitor
Program
Program
Program
Program
Program
or
2
) keys to edit it.
1
MONITOR
PROGRAM
"D" Group
"D" Group
"A" Group
"B" Group
"C" Group
"F" Group
"H" Group