Example Wiring Diagram - Hitachi SJ100 Instruction Manual

Sj100 series
Hide thumbs Also See for SJ100:
Table of Contents

Advertisement

Example Wiring Diagram

The schematic diagram below provides a general example of logic connector wiring, in
addition to basic power and motor wiring covered in Chapter 2. The goal of this chapter
is to help you determine the proper connections for the various terminals shown below
for your specific application needs.
Breaker,
MCCB or GFI
Power source,
3-phase or
1-phase, per
inverter model
Intelligent inputs,
6 terminals
Forward
NOTE: For the wir-
ing of intelligent I/O
Reverse
and analog inputs, be
sure to use twisted
pair / shielded cable.
Attach the shield wire
for each signal to its
respective common
terminal at the
inverter end only.
Thermistor
Logic input common
Meter
Analog reference
0–10VDC
Analog common
R
(L1)
S
(L2)
T
N(L3)
P24
1
Input
circuits
2
3
4
[5] configurable as
discrete input or
thermistor input
5
6
L
FM
H
O
4–20mA
OI
L
SJ100 Inverter
SJ100
U
(T1)
V
(T2)
W
(T3)
+1
24V
+
+
RB
Braking
resistor (optional)
AL1
AL0
AL2
Open collector outputs
Output
circuits
12
Freq. arrival signal
11
Logic output common
CM2
4–5
Motor
DC reactor
(optional)
Braking
unit
(optional)
Alarm contacts,
type 1 Form C
Run signal
Load
Load
+

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents