3–44
"H" Group: Motor Constants Functions
Func.
Name /
Code
SRW Display
H204 Motor poles setting, 2nd
motor
2AUXP
H_05 Motor speed constant
AUX KP
H205 Motor speed constant,
2nd motor
2AUXKP
H_06 Motor stabilization
constant
AUX KCD
H206 Motor stabilization
constant, 2nd motor
2AUXKCD
H_20 Motor constant R1
AUX R1
H220 Motor constant R1, 2nd
motor
2AUXR1
H_21 Motor constant R2
AUX R2
H221 Motor constant R2, 2nd
motor
2AUXR2
H_22 Motor constant L
AUX L
H222 Motor constant L,
2nd motor
2AUXL
H_23 Motor constant I
AUX I0
H223 Motor constant I
motor
2AUXI0
"H" Function
Description
Four selections:
2 / 4 / 6 / 8
4p
Motor proportional gain
constant (factory set),
20
range is 0 to 99
Motor proportional gain
constant (factory set)
range is 0 to 99
20
Motor constant (factory set),
range is 0 to 255
100
Motor constant (factory set),
range is 0 to 255
100
Range is 0.000 to 65.53,
0.000 to 9.999
05.700*
10.00 to 65.53
Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53
05.700*
Range is 0.000 to 65.53,
0.000 to 9.999
02.773
10.00 to 65.53
Range is 0.000 to 65.53,
0.000 to 9.999
10.00 to 65.53
02.773
Range is 0.00 - 655.3 mH,
0.00 to 99.99
045.70mH
100.0 - 655.3
Range is 0.00 - 655.3 mH,
0.00 to 99.99
100.0 - 655.3
045.70mH
Range is 0.00 to 655.3 Amps,
o
0.00 to 99.99
001.50A
100.0 - 655.3
, 2nd
Range is 0.00 to 655.3 Amps,
o
0.00 to 99.99
100.0 - 655.3
001.50A
Defaults
Run
Mode
–FE
–FU
–FR
Edit
(CE)
(UL)
(Jpn)
✘
4
4
✘
20
20
✘
20
20
✘
100
100
100
✘
100
100
100
✘
Factory set according
to inverter model
✘
Factory set according
to inverter model
✘
Factory set according
to inverter model
✘
Factory set according
to inverter model
✘
Factory set according
to inverter model
✘
Factory set according
to inverter model
✘
Factory set according
to inverter model
✘
Factory set according
to inverter model
Units
4
poles
20
—
20
—
—
—
Ohms
Ohms
Ohms
Ohms
mH
mH
Arms
Arms