Hitachi SJ100 Instruction Manual page 112

Sj100 series
Hide thumbs Also See for SJ100:
Table of Contents

Advertisement

3–40
"C" Group: Intelligent Terminal Functions
Analog Function Summary Table – This table shows all three functions for the analog
output [FM] (frequency meter) terminal. Detailed descriptions, related parameters and
settings, and example wiring diagrams are in
page
4–33.
Option
Code
00
01
02
Analog Function Summary Table
Function Name
Analog Frequency
Monitor
Analog Current Output
Monitor
Digital Frequency
Output Monitor
"Analog and Digital Monitor Output" on
Description
PWM (pulse-width-modulated) voltage output that has a
duty cycle proportional to the inverter output frequency
PWM (pulse-width-modulated) voltage output that has a
duty cycle proportional to the inverter output current to the
motor. It reaches 100% duty cycle when the output
reaches 200% of the rated inverter current.
FM (frequency-modulated) voltage output with a constant
50% duty cycle. Its frequency = inverter output frequency.

Hide quick links: