3–10
"A" Group: Standard Functions
Func.
Name /
Code
SRW Display
A203 Base frequency setting,
2nd motor
2F-BASE
A_04 Maximum frequency
setting
F-MAX
A204 Maximum frequency
setting, 2nd motor
2F-MAX
Analog Input Settings
The inverter has the capability to accept an external analog input that can command the
output frequency to the motor. Voltage input (0 –10V) and current input (4–20mA) are
available on separate terminals ([O] and [OI], respectively). Terminal [L] serves as
signal ground for the two analog inputs. The analog input settings adjust the curve
characteristics between the analog input and the frequency output.
In the graph below (left), A_13 and A_14 select the active portion of the input voltage or
current range. The parameters A_11 and A_12 select the start and end frequency of the
converted output frequency range, respectively. Together, these four parameters define a
line segment as shown (below, right). When the line does not begin at the origin, A_15
defines whether the inverter outputs 0Hz or the A_11 frequency when the analog input
value is less than the A_13 setting (determines the non-linear part of the translation).
Frequency
A 12
A 11
0
0V
4mA
"A" Function
Description
Settable from 50 Hz to the
maximum frequency
060Hz
Settable from the base
frequency up to 360 Hz
060Hz
Settable from the base
frequency up to 360 Hz
060Hz
10V
A 13
A 14
20mA
% Input scale
Run
Mode
Edit
Frequency
A 12
A_15 = 00
A 11
0
%
0V
A 13
4mA
% Input scale
Defaults
–FE
–FU
–FR
Units
(CE)
(UL)
(Jpn)
50.0
60.0
60.0
Hz
50.0
60.0
60.0
Hz
50.0
60.0
60.0
Hz
A_15 = 01
%
10V
A 14
20mA