OIL SHUTDOWN

The oil service has two modes:
Shutdown = ON
Counter with Shutdown: The operator sets the
number of product cook cycles before oil service
action is taken by the controller. After that number
of cook cycles has elapsed, the heat will be shut
off, a SERVICE OIL message will be flashed on
the display, and the keypad will be locked out.
Turning the fryer off, then on, will clear the condition
and restore the count set by COUNT = XXX in the
following section.
Shutdown = OFF
Timer without Shutdown: The controller keeps
track of the number of hours since OIL TM = XXX
HR was set by the operator. When the time has
elapsed, a small oil indicator light will turn on.
Service of the fryer is not interrupted. The oil
indicator remains lit until a time is re-entered for
OIL TM = XXX HR in the following section. Turning
the fryer off, then on, will clear the indicator.
DISPLAY
READY
-FUNCTIONS-
EDIT PRODUCT
SEL SETBACK
CALIBRATE
BOIL OUT
RECOVERY
SELECT MELT
MANUAL SETUP
OIL SHUTDOWN
COUNT ON
COUNT OFF
OIL SHUTDOWN
-FUNCTIONS-
READY
INSTRUCTION
Press 2 & 3 simultaneously.
Press
.
Press
.
Press
.
Press
.
Press
.
Press
.
Press
.
Press
.
Press ENTER.
Press
or
to toggle.
When OK, press EXIT.
Press EXIT.
Press EXIT.
OIL TRM/CNTR
DISPLAY
READY
-FUNCTIONS-
EDIT PRODUCT
SEL SETBACK
CALIBRATE
BOIL OUT
RECOVERY
SELECT MELT
MANUAL SETUP
OIL SHUTDOWN

OIL TMR/CNTR

OIL TM = XXX HR /
COUNT = XXX
OIL TMR/CNTR
-FUNCTIONS-
READY
If Oil Shutdown is OFF:
The controller will alert the operator when the oil
needs to be changed. OIL TM = XXX sets the
number of hours before the alert will be given.
If Oil Shutdown is ON:
The controller will shut off the heat, lock out the
keypad, and signal to service the oil. The fryer must
be turned off to clear this condition. COUNT = XXX
sets the number of cook cycles before shutoff.
Turning the fryer off, then on, automatically restores
COUNT = XXX to the number originally set by the
operator.
— 22 —
INSTRUCTION
Press 2 & 3 simultaneously.
Press
.
Press
.
Press
.
Press
.
Press
.
Press
.
Press
.
Press
.
Press
.
Press ENTER.
Press
or
to reset the
timer or counter. When set
time/count is OK, press EXIT.
Press EXIT.
Press EXIT.