Interfaces

RS-232 Interface

"uart1:"
Intermec EasyCoder F4 – Installation & Operation Ed. 3
The EasyCoder F4 has, as standard, two serial communication
interfaces: RS-232 on "uart1:" and USB (see next page).
Protocol
Default setup:
Baud rate:
9600
Char. length
8 bits
Parity:
None
Stop bits:
1
RTS/CTS
Disabled
ENQ/ACK:
Disabled
XON/XOFF:
Disabled (both ways)
New Line:
CR/LF
To change the serial interface settings, see Chapter 7, "Setting
Up the Printer".
Interface Cable
Computer end:
DB-9pin or DB-25pin female connector (PC)
Printer end:
DB-25pin male connector
Host
Signal
DB-9 DB-25
1
RXD
2
TXD
3
CTS
8
RTS
7
GND
5
16
DSR
6
20
22
1
/. The external +5V is limited to 200 mA and is automatically
switched off at overload. It is intended to drive for example an external
alphanumeric keyboard connected to the RS-232 port.
EasyCoder F4
Signal
DB-25 DB-25 Signal
1
2
TXD
3
RXD
4
RTS
5
CTS
6
DSR
7
Signal GND
1
+ 5V
DTR
20
RI
22
Appendix 3
Host
1
1
shield
2
3
RXD
3
2
TXD
4
5
CTS
5
4
RTS
6
20
DTR
7
7
GND
16
6
DSR
105