Troubleshooting Guide - Chauvet Lrgrnd 300E Beam User Manual

Hide thumbs Also See for Lrgrnd 300E Beam:
Table of Contents

Advertisement

Troubleshooting Guide

Symptom
Fixture does not power up
Fixture powers up but
lamp does not ignite
Lamp ignited but has low
intensity/color
temperature
Lamp flickers or turns off
by itself
Circuit breaker/fuse keeps
tripping/blowing
Fixture does not respond
to DMX when nearby
fixtures on the same
universe do
DMX signal problems
(see Appendix > DMX
Primer)
Legend 300E Beam User Manual Rev. 01f
Cause(s)
No power on outlet
Blown fuse
Bad power cord/plug
Bad power switch
Bad power supply
Bad main controller
State/Power On parameter set to
NO
Lamp temperature problems
Lamp problems
Dimmer not at full output
Lamp still cold
CTC or CMY filter interfering
Defective or old lamp
Misaligned lamp
Defective lamp wires or socket
Defective ballast
Defective or old lamp
Temperature problems
Defective lamp wires or socket
Defective ballast
Excessive circuit load
Short circuit along the power wires •
Wrong DMX addressing
Damaged DMX cables
Wrong polarity on the controller
Loose DMX cables
Faulty DMX interface
Faulty Display/Main board
Non DMX cables
Bouncing signals
Long cable / low level signal
Too many fixtures
Interference from AC wires
If you still experience technical problems after trying the above solutions, contact
CHAUVET® Technical Support.
Technical Information
Action(s)
Repair outlet problem or use another outlet
Replace blown fuse with same type and rating
fuse
Repair or replace power cord/plug
Replace power switch
Replace power supply
Replace main controller
Change parameter to YES
Check error messages and follow instructions
Check error messages and follow instructions
Adjust dimmer value
Wait for lamp to come up with full output
temperature
Set color wheel or filter to home position
Replace lamp
Realign lamp
Repair/change wiring or socket
Replace ballast
Replace lamp
Check error messages and follow instructions
Repair/change wiring or socket
Replace ballast
Check total load placed on the electrical circuit
Check for a short in the electrical wiring
Check DMX mode and starting DMX address
Check DMX cables
Check polarity switch settings on the controller
Check cable connections
Replace the Main board
Replace the Main board
Use only DMX compatible cables
Install terminator as suggested
Install an optically coupled DMX splitter right after
the fixture with the strong signal
Install an optically coupled DMX splitter after unit
#32 or before
Keep DMX cables separated from power cables or
fluorescent/black lights
-25-

Advertisement

Table of Contents
loading

Table of Contents