Line CHAUVET® products’ manuals from www.chauvetlighting.com. Document The Legend 300E Spot User Manual Rev. 01g supersedes all previous versions of this manual. Please discard any older versions of this manual you may have, whether in Revision printed or electronic format, and replace them with this version.
“COLORado™ UM” MENU > Settings Icon Meaning The term “DMX” used throughout this document refers to the USITT DMX512-A transmission protocol. Legend 300E Spot User Manual Rev. 01g One Legend 300E Spot Two omega clamps Three additional gobos One Warranty Card...
· · · In the unlikely event that your Legend 300E Spot may require service, please contact CHAUVET® Technical Support. Avoid direct eye exposure to the light source while the fixture is on. Always disconnect this product from its power source before servicing.
2. Introduction Product The Legend 300E Spot is a compact, electronic moving yoke spot fixture equipped with a 300-watt HID lamp. It includes a color wheel with eight slots plus white. It also comes Description with two gobo wheels, one with seven rotating slot-n-lock gobos plus open, and the other with eight fixed gobos plus open.
0 to 100% switch. AC Plug The Legend 300E Spot comes with a bare ended power input cord. The fixture side of this power cord enters the fixture through a strain reliever (rubber boot) and it cannot be disconnected from the fixture.
Setup The Legend 300E Spot comes with two gobo wheels. Gobo wheel #1 has seven rotating Gobo Wheels gobos, while gobo wheel #2 has eight fixed gobos, as indicated below. The diagram shows the first and last gobo on each wheel, as per the DMX Values tables.
Setup Gobo The gobos in the Legend 300E Spot’s gobo wheel are removable from their gobo plates. This operation is quite simple, although it requires the technician to be careful and to Replacement follow the recommended procedure. · · ·...
Lamp The Legend 300E Spot is equipped with a Philips MSR Gold 300/2 lamp. This lamp uses a socket called FastFit, which allows for fast and easy lamp changes. Follow the Replacement procedure below to safely change the Legend 300E Spot’s lamp.
· Procedure The Legend 300E Spot comes with an already installed mounting bracket to which you will be able to attach the two included omega clamps. Be aware that you will have to use two mounting points per fixture. In addition, you will have to use a safety cable (not included) to link the fixture to the structure.
You can set the Legend 300E Spot start address in the 001~512 DMX range. This allows for the control of up to 17 fixtures in the 29-channel Mode 2. The Legend 300E Spot works with any compatible DMX controller using standard DMX cables or the optional W-DMX receiver.
Select YES to enable retransmission or NO to deactivate retransmission. b) Accept the selected option. window will open). a) Select YES to reset the memory or NO to exit without resetting. b) Accept the selected option. Legend 300E Spot User Manual Rev. 01g...
1) Highlight Bl.o Gobo Change (the current setting will show). 2) To black out the output when the gobo wheel changes, press <ENTER> (a pop up Legend 300E Spot User Manual Rev. 01g a) Select YES to reverse the pan direction or NO to use the normal pan direction.
Select the delay before the lamp strikes after power up in seconds (0~255). b) Accept the new value. a) Select the delay before the fixture powers off after lamp off in seconds (0~255). b) Accept the new value. Legend 300E Spot User Manual Rev. 01g...
5) When done with the test, exit to the previous menu (the values of all tested channels Legend 300E Spot User Manual Rev. 01g a) Select YES to turn the LCD around (fixture hanging from a truss) or NO to keep the normal LCD view (fixture standing on a surface).
Select YES to reset the iris and flatb to their home positions. b) Accept the selected option. a) Select YES to reset all moving optical parts and the moving head to their home positions. b) Accept the selected option. Legend 300E Spot User Manual Rev. 01g...
1) Select Cyan and press <ENTER> (a pop up window will open). Magenta 1) Select Magenta and press <ENTER> (a pop up window will open). Legend 300E Spot User Manual Rev. 01g interval and remaining time will show). pop up window will open).
Page 22
Select the new value (0~255). b) Accept the new value. a) Select the new value (0~255). b) Accept the new value. a) Select the new value (0~255). b) Accept the new value. Legend 300E Spot User Manual Rev. 01g...
Fixture Use Time Fixture Information Lamp On Time Firmware Version Reset Functions Shutter/Dimmer Focus/Zoom/Prism/Frost Fixture Maintenance Special Functions Factory Setting Legend 300E Spot User Manual Rev. 01g Level Level DMX Address 001~512 Mode 1 (21-channel) Mode 2 (29-channel) Active Retransmit WDMX card)
190 ó 193 Stop 194 ó 255 Slow~Fast CCW rotation 000 ó 127 Index 128 ó 189 Fast~Slow CW rotation 190 ó 193 Stop 194 ó 255 Slow~Fast CCW rotation Continues on the next page Legend 300E Spot User Manual Rev. 01g...
Page 25
Channel Function (Cont.) Gobo 2 Focus Zoom Prism R-Prism Iris Frost Function Legend 300E Spot User Manual Rev. 01g Continued from the previous page Value Percent/Setting 000 ó 005 Open 006 ó 010 Gobo 8 011 ó 015 Gobo 9 016 ó...
194 ó 255 Slow~Fast CCW rotation 000 ó 127 Index 128 ó 189 Fast~Slow CW rotation 190 ó 193 Stop 194 ó 255 Slow~Fast CCW rotation 000 ó 255 0~100% Continues on the next page Legend 300E Spot User Manual Rev. 01g...
Page 27
Gobo 2 Focus Zoom Prism R-Prism R-Prism Fine Iris Frost Pan/Tilt Macro Legend 300E Spot User Manual Rev. 01g Continued from the previous page Value Percent/Setting 000 ó 005 Open 006 ó 010 Gobo 8 011 ó 015 Gobo 9 016 ó...
Page 28
Focus / zoom / prism / frost reset 190 ó 199 Iris / flatb reset 200 ó 209 Reset all 210 ó 229 No function 230 ó 239 Lamp off 240 ó 249 Enable Flatb 250 ó 255 Disable Flatb Legend 300E Spot User Manual Rev. 01g...
Dust build up reduces light output performance and can cause overheating. This can lead to reduced light source life and increased mechanical wear. CHAUVET® recommends cleaning the fixture’s external optics with a soft cloth using normal glass cleaning fluid. To clean a fixture, follow the recommendations below: ·...
Check main control board · Check part’s free movement and integrity · Check sensors’ wiring and position · Check stepper motor, belt, and driver board · Check the corresponding control board · Check main control board Legend 300E Spot User Manual Rev. 01g...
Too many fixtures · Interference from AC wires If you still experience technical problems after trying the above solutions, contact CHAUVET® Technical Support. Legend 300E Spot User Manual Rev. 01g Technical Information Action(s) · Repair outlet problem or use another outlet ·...
The carrier is responsible for any damage incurred during shipping. Therefore, if the received merchandise appears to have damages caused during shipping, the customer must submit the damage report and any related claims with the carrier, not CHAUVET®. The customer must submit the report upon reception of the damaged merchandise.
DMX Channels ... 21 and 29 Ordering Information Legend 300E Spot ... LEGEND300SPOT Two Legend 300E Spot units in a single road case ... LEGEND300SPOTX2 Warranty Information Warranty duration ... 2-year limited warranty Legend 300E Spot User Manual Rev. 01g...