Technical Information
Error Messages
Message
Lamp Startup Fail
Temperature Sense Error
Lamp too Hot Low Power
Lamp Too Hot Power Off
Maintenance Fixture
Lamp On Over 700 Hour
Memory Initial Fail
CPU-B Error
CPU-C Error
CPU-D Error
Pan Reset Error
Pan Encode Error
Tilt Reset Error
Tilt Encode Error
Shutter Reset Fail
Dimmer Reset Fail
Color Reset Fail
Cyan Reset Fail
Magenta Reset Fail
Yellow Reset Fail
Gobo Reset Fail
R-Gobo Reset Fail
Effect Reset Fail
R-Effect Reset Fail
Frost Reset Fail
-24-
Cause(s)
The lamp has not started after being
struck
No communication with temperature
sensor
Ambient temperature higher than 105º
C; lamp in low power for safety
Ambient temperature higher than 110º
C; lamp off for safety
Fixture Maintenance timer expired
Lamp change is overdue
Memory chip error
No communication with auxiliary CPU
Moving head failed going to home
position after power up or fixture reset
Indicated moving part failed to go to its
home position after power up or fixture
reset
Action(s)
•
Check lamp
•
Check lamp socket and wiring
•
Check ballast and igniter
•
Check sensor wiring
•
Check sensor integrity
•
Check control board
•
Check fans
•
Check fan wiring
•
Clean vents
•
Check fans
•
Check fan wiring
•
Clean vents
•
Proceed with maintenance and reset timer
•
Change lamp
•
Change main board
•
Check sensors wiring and position
•
Check stepper motor, belt, and driver board
•
Check control boards
•
Check moving head's free movement
•
Check sensors' wiring and position
•
Check stepper motor, belt, and driver board
•
Check the corresponding control board
•
Check main control board
•
Check part's free movement and integrity
•
Check sensors' wiring and position
•
Check stepper motor, belt, and driver board
•
Check the corresponding control board
•
Check main control board
Legend 300E Beam User Manual Rev. 01f