~LAxx
This command sets the passing threshold for the Overall ISO method Symbol
Grade. For example: ~LA28 causes an Overall Symbol Grade of 2.7 or lower
calculated for the code analyzed to set a failure condition for this parameter.
~Hx
This command stores all parameters into non-volatile memory. This command
should be the last command sent after parameters are programmed via the
above commands.

Mode 16 (~LV16)

Mode 16 I/O operation
1. System will operate in Edge Sync or Envelope sync mode (~LX#).
2. Sync polarity programmable (~LP#)
3. Use ~PR0200 for proper port initialization.
4. Port 1 will pulse active ON for a bar code quality error condition.
5. Port 2 will pulse active ON for a NO READ, partial or low % decode error
condition.
6. Port 3 will pulse active ON for a non-error condition.
7. Port pulse times programmable. (~PP801xxx)
8. Pulses act like re-triggerable 1-shot logic
9. Pushing the reset button or power re-cycle will place Ports 1, 2 and 3 in their
inactive states and reset the # codes per sync counter.
10. Error conditions available are:
a. Partial Read (Programmable, ( ~Lp#, LQ#)
b. % decode (Programmable, ~LD##)
c. Bad Quiet Zone: < 10X (~PB816xxx100)
d. ISO Defects grade less than B (Programmable, ~PB806xxx000)
e. ISO Decodability grade less than C (Programmable, ~PB802xxx100)
f.
Symbol Contrast grade less than D (Programmable, ~PB804xxx100)
g. Overall ISO Grade (Programmable, ~LAxx)
h. No Read (if sync is received)
i.
Number of codes per sync programmable (~LN##, ~LZ##)