Hand Held Products SV Series User Manual page 91

Bar code scanner/verifier
Table of Contents

Advertisement

m. I 2 of 5 optional Mod 10 Check Digit data error (if enabled)
n. Data Match Error
o. Increment or Decrement data Error (~Br).
LED Operation
1. LED1 will turn on when Port 1 is active due to ISO, Symbol Contrast, X
dimension, ratio, mod check or quiet zone error conditions.
2. LED1 will flash when Port 1 is active due to a data increment or decrement
error condition.
3. LED2 will turn on when Port 2 is active due to a partial, % decode or no read
error conditions.
4. LED2 will flash when Port 1 is active due to a Data Match error condition.
5. Flashing on indication will override a solid indication if both types of error
conditions occur.
Note: Both LEDs can be on in cases where multiple bar codes are analyzed in
a sync period.
SV Commands Important for Mode 17
This system is operating in a "mode" rather than fully programmable logic. The
port activation parameters are programmable via the ~PB8 rather than ~PB1,
~PB2, etc. for each individual port. Other commands, such as mode commands
are also available. The commands most useful for this system application are
described below.
~LV17
This command sets this mode of operation.
~Lp0
This command turns off all partial decode logic at the decoder level
~Lp1
This command turns on partial decode logic at the decoder level
~LQ1
This command allows partial decodes to activate the output ports
~LQ0
This command disables partial decodes to activate output ports.
~LAxx
This command sets the passing threshold for the Overall ISO method Symbol
Grade. For example: ~LA28 causes an Overall Symbol Grade of 2.7 or lower
calculated for the code analyzed to set a failure condition for this parameter.
Quick Check® SV Series User's Guide
(~BC).
6 - 43

Advertisement

Table of Contents