Hand Held Products SV Series User Manual page 85

Bar code scanner/verifier
Table of Contents

Advertisement

d. ISO Defects grade programmable (~PB806xxx000)
e. ISO Decodability grade programmable (~PB802xxx100)
f.
Symbol Contrast grade programmable (~PB804xxx100)
g. No Read (if edge sync is received)
h. Number of codes per sync programmable (~LN##, ~LZ##)
i.
Overall ISO Grade (Programmable, ~LAxx)
j.
Symbology modulo check digit
Mode 12 LED Operation
1. LED1 will turn on if Ports 1-4 go active due to ISO, contrast, or quiet zone
failure
2. LED2 will turn on if Ports 1-4 go active due to a partial or no read condition
Note: Both LEDs can be on in cases where multiple bar codes are analyzed in
a sync period.
SV Commands Important to Mode 12
This system is operating in a "mode" rather than fully programmable logic. The
port activation parameters are programmable via the ~PB8 rather than ~PB1,
~PB2, etc. for each individual port. Other commands, such as mode commands
are also available. The commands most useful for this system application are
described below.
~LV12
This command sets this mode of operation.
~Lp0
This command turns off all partial decode logic at the decoder level
~Lp1
This command turns on partial decode logic at the decoder level
~LQ1
This command allows partial decodes to activate the output ports
~LQ0
This command disables partial decodes to activate output ports.
Quick Check® SV Series User's Guide
6 - 37

Advertisement

Table of Contents
loading

Table of Contents