Jenn-Air D ualFuelUpdraft S lide-InRange
PLEASEKEEPTHIS MANUAL FOR FUTUREREFERENCE
This manual is intended to assist in the initial installation and adjustments of the range.
• Only qualified personnel should install or service this range.
• Read "Safety Instructions"
in Use & Care book before using range.
• Improper installation, adjustment, alteration, service, maintenance or use of range
can result in serious injury or property damage.
• Installer, take care not to damage flooring.
S
Donot lift or move range by graspingdoor handles,main
top, or backguard.
This range has been designed in accordancewith the
requirementsof varioussafety agencies and complies
with the maximum allowable wood cabinet
temperatures of 194°EIf this range is installed with
cabinetsthat havea lower working temperature than
194°F, d iscoloration, delamination or melting may occur.
Placerange in a well lit area. Do not set range over
holes in the floor or other locationswhere it may be
subject to strong drafts. Any opening in the wa I behind
the range and in the floor under the range should be
sealed. Makesure the flow of cooling/ventilation air is
not obstructed below the range. Note:A range should
NOTbe installed over kitchen carpeting.
HighAltitudeNotice: The specified gas burner ratings
,Arisk of range tip-over exists if the appliance is not installed in accordance with the
provided installation instructions. The proper use of the ANTI-TIPdevice minimizes
the risk of TIP-OVER. I n using this device the consumer must still observe the safety
precautions as stated in the USEand CAREMANUALand avoid using the oven doors
as a step stool. Installation instructions are provided for wood and cement in either
floor or wall. Any other type of construction may require special installation
techniques as deemed necessaryto provide adequate fastening of the ANTI-TIP
bracket to the floor or wall. The bracket may be installed to engage the LEFTor
RIGHT rear leveling foot. NOTE: T he bracket provided is designed for use with flush
mount and non-flush mount outlet receptacles. Install the bracket with the
orientation hole in the longer leg against the wall or floor as shown in steps 14-19.
MOBILE HOMES
The installation of a range designed for mobile home installation must conform with
the Manufactured HomeConstruction and Safety Standard,Title24 CFR,Part 3280
(formerly the Federal Standardfor Mobile Home Construction and Safety,Title24
HUD,Part280) or, when such standard is not applicable,the Standardfor Manufactured
Home InstallationsANSIA225.1/NFP,A 501,A,or with local codes. In Canadathe range
must be installed in accordance with the current CS,AStandardC22.1 - Canadian
Electrical Code Part 1 and Section Z240.4.1 - Installation Requirementsfor Gas
Burning ,Appliancesin Mobil Homes (CS,A Standard C,AN/CS,A - Z240MH).
typically
apply to e!evat onsup to 2000 feet. For higher
a!titudes,the rates may need tobe reducedto achieve
satisfactory operation. A local certified gasservicer will
be able to advise if a reduction is necessary,
Requirements
forPropane,Appliances
andEquipment inR.V.'s (CS,A Standard
C,AN/CSA - Z240 RVSeries).
RECREATIONAL
PARK TRAILERS
The installation of a range designed for recreational park trailers must conform with
state or other codes or, in the absenceof such codes, with the Standard for
Recreational Park Trailers,ANSI,A119.5-latest edition. In Canadathe range must be
installed in accordance with C,AN/CS,A - Z240.6.2 - Electrical Requirementsfor R.V.'s
(CS,A Standard C,AN/CS,A - Z240 RVSeries) and SectionZ240.4.2 - Installation
i i; I=11
The range must be installedin accordancewith Local andNational ElectricCode
(NEC) ANSI/NFP,A N o.70-latest edition, or CanadianElectric CodeCSASTB.C221
latestedition. Seerating plate for total connected KW rating.
ElectricalSupply Connection
The rangerequires120 volts,60 cyclealternatingcurrent from a dedicated
groundedoutletwith a 15 amp circuit breaker. See serial platefor rating,located
on front frame behindstorage drawer.Usermay experienceoccasionalcircuit
trippingif Ground Fault Circuit Interrupter (GFCl)outletor breaker is in use.
Mostlocal Building Regulationsand Codesrequirethat all electricalwiringbe doneby
licensedelectricians.,Allwiring shouldconform to Local andNational ElectricalCodes.
This rangerequires a single phasethree wire 120/240 or a 120/208 volt,60 Hz,AC
circuit. Wiring codes requirea separate circuit be run from the main entrancepanel to
the range andthat it be equippedwith separatedisconnectswitch and fuses,either in
the main entrance panel or in a separateswitch and fuse box.
Theelectricalconnection to this unit is designed only for use with a flexiblepowercord.All
unitsare shipped with a speciallydesigned 4-wire servicecord.This cordshouldbe usedon