Video Loss: click the camera number (01 to 16) to set the alarm condition when video is lost. Click
Detail button to setup the system to send out the alarm when video is lost and status last the time that
user has entered in Continuous trigger duration.
6. In (5) Sensor, select and click on the sensor number to set the condition for the system to alarm. If the
sensor normal status is high, set the sensor condition to low.
-
Continue trigger duration: Set a time period that when sensor has been trigger and stay in the same
status for that period, then the alarm will be sent out.
-
Enable/disable the Abnormal Event check box, to set the condition of the event for system to alarm.
System Reboot: when the DVR system reboot without abnormal condition, the system will send
out the alarm message.
Abnormal Reboot: when the DVR system reboot in irregular condition, the system will send out
the alarm message.
Recording is switched off: when the recording has been stopped, the system will send out the
alarm message.
Network is switched off: when the network connection of DVR system is lost, the system will
send out the alarm message.
Hard Disk failed: when the hard disk doesn't work normally, the system will send out the alarm
message.
7. In (6) Alarm Reset, click the camera number to set the reset condition of alarm. Once alarm is reset, all
alarm action will stop at the moment. If the sensor normal status is high, set the alarm reset condition to low.
8. In (7) Action, you may now set the alarm action for the system to perform when the alarm condition is
activated.