C. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing or fi nishing material closer than
the minimums listed must be constructed entirely of non-
combustible materials (i.e., steel studs, concrete board, etc).
When installing a mantel, provisions must be made
in order to secure the mantel to the adjacent framing
materials. For example, lintel brackets or lag bolts may
be considered for this purpose.
Combustible Mantel Legs or Wall Projections
FIREPLACE
OPENING
14 IN. MIN.
FACTORY-SUPPLIED
NON-COMBUSTIBLE BOARD
COMBUSTIBLE OR
NON-COMBUSTIBLE WALL
Figure 13.6 Combustible Mantel Leg and Wall Projections
Non-Combustible Mantel Legs or Wall Projections
NON-COMBUSTIBLE
SEE SECTION 13.E
FOR REQUIRED
CLEARANCES
FIREPLACE
OPENING
14 IN. MIN.
FACTORY-SUPPLIED
NON-COMBUSTIBLE
BOARD
Figure 13.7 Non-Combustible Mantel Leg and Wall Projections
1/2 IN. BUILDING MATERIAL
COMBUSTIBLE
COLUMN
4 IN. MAX.
7 IN.
MIN.
1/2 IN. BUILDING MATERIAL
COLUMN
6 IN. MAX.
COMBUSTIBLE OR
NON-COMBUSTIBLE
WALL
Heat & Glo •
TRUE-36, TRUE-42, TRUE-50 • 2282-900 Rev. i •
Non-Combustible Zone
1/2 IN. BUILDING MATERIAL
(MAY BE COMBUSTIBLE)
NO COMBUSTIBLES
IN HATCHED AREA
1 IN.
FACTORY-SUPPLIED
1/2 IN.
NON-COMBUSTIBLE
BOARD
Figure 13.8 Non-Combustible Zone
4/13
PIPE IS FOR VISUAL
REFERENCE ONLY
39 IN.
= COMBUSTIBLES
NOT ALLOWED
49