Table 5-1.
Remote Node Profile Menu Fields for Dial-up Line Applications (continued)
Field
Edit PPP Options
IP Addr
Edit IP/IPX/Bridge Options
Edit Script Option
Telco Options:
Allocated Budget
(min)
Period (hr)
Session Option:
Input Filter Sets,
Output Filter Sets and
Call Filter Sets
Description
To edit the PPP options for this Remote Node, move the
cursor to this field, use the space bar to select [Yes] and
press [Enter]
. This will bring you to Menu 11.2 -
Remote Node PPP Options. For more information on
configuring PPP options, see the section Editing PPP
Options.
This is a required field [?] if [Route] is set to [IP]. Enter
the IP address of this Remote Node.
To edit the parameters, select [Yes] and press [Enter].
This will bring you to Menu 11.3 - Remote Node Network
Layer Options. For more information on this screen,
refer to the chapter pertaining to your specific protocol.
To edit the parameters, select [Yes] and press [Enter].
This will bring you to Menu 11.4 - Remote Node Script
Options.
This field will set a budget outgoing call time for the
Remote Node. The default for this field is [0] for no
budget control.
This field will set the time interval to reset the above
outgoing call budget control.
In these fields, select which filter set(s) you would like to
implement to filter the incoming and outgoing traffic
between this Remote Node and your Prestige. You can
choose from 12 different filter sets. In addition, you can
link up to 4 filter sets together for further customization
(for example, 1, 5, 9, 12).
Note that spaces are accepted in this field.
For more information on customizing your filter sets, see
Chapter 9. The default is blank, that is, no filters defined.
Chapter 5 Remote Node Configuration for LAN-to-LAN
Prestige 128MH PSTN Router/Hub
Press space bar
Press space bar
Default=Blank
Options
to toggle
[Yes]
then press
[Enter]
to toggle
[Yes]
then press
[Enter]
[Yes]
then press
[Enter]
Default = 0