Mounting OS6250 Switches

Mounting OS6250 Switches
Once the OS6250 is assembled it can now be mounted either in a rack, on a wall, or on a table.
Note. Only the OS6250-8M supports wall-mounting. (OS6250-WALL-MNT kit required).

Rack-Mounting OS6250 Switches

General Rack-Mounting Guidelines

If you will be rack-mounting your OS6250 switch(es), refer to the important guidelines below before
installing.
It is recommended that two people install the switch assembly on the rack—one person to hold the
chassis and position it on the rack, and a second person to secure the chassis to the rack using
attachment screws. (Please note that Alcatel-Lucent does not provide rack-mount screws. Use the
screws supplied by the rack vendor.)
To prevent a rack from becoming top heavy, it is recommended that you install heavier equipment at
the bottom of the rack, whenever possible.
Review
page 3-4
If you are installing the switch on a relay rack, be sure to install and secure the rack per the rack
manufacturer's specifications.

Rack-Mounting Installation

1
Follow the proper assembly instructions based on the configuration of the chassis and power supply
trays described in
"Assembling OS6250 Switches" on page
2
Attach rack mount ears to both sides of the front of the chassis.
3
Using one additional person, lift and position the assembly on the rack until the rack-mount flanges are
flush with the rack post.
4
Align the holes in the flanges with the rack holes.
OmniSwitch 6250 Hardware Users Guide
for recommended chassis clearances before installing.
Attach Rack Mount Brackets
June 2012
Mounting OS6250 Switches
3-6.
page 3-15