Setting The Delay Time; Setting The Search Frequency Step - Uniden UBC800XLT Owner's Manual

Scanner radio with trunk tracker iii and automatic scanning capabilities
Table of Contents

Advertisement

UB356ZH.fm Page 102 Wednesday, December 19, 2007 11:28 AM
On — the scanner stops briefly on the channel, but then immediately resumes
scanning automatically.
Off — the scanner remains on the channel until the transmission stops. The
default setting is Off.
Note: If you are trying to test the Close Call feature with a nearby transmitter (such
as a CB) and you do not talk into the transmitter, the scanner detects this
unmodulated carrier as data and skips the frequency when Data Skip is on. Turn
the feature off or talk into the transmitter to modulate the carrier.
This setting is ignored for AM/WFM/FMB channels.

Setting the Delay Time

[MENU]
Srch/CloCall Opt
Set Delay Time
This setting determines how long the scanner waits after a transmission ends
before resuming Quick Search or Close Call operation.
1-5 sec — The scanner waits the set amount of time after the transmission ends
before resuming. The default setting is 2 sec.
Off — The scanner resumes immediately when the transmission ends.

Setting the Search Frequency Step

[MENU]
Srch/CloCall Opt
F
Set Step
This setting lets you select the frequency step used during Quick Search.
Auto — The step is based on the band (see the table at the front of the manual).
This is also the default setting.
5.0 kHz, 6.25kHz,
8.33kHz, 10.0 kHz,
12.5 kHz, 15.0 kHz,
20.0 kHz, 25.0 kHz,
50.0 kHz, 100.0 kHz
102
F
F
F
The scanner uses the selected step.