C. LOCATE FIELD WIRING COMPARTMENT -
120 V, 60 HZ (-J1 MODELS ONLY)
WARNING: Risk of electrical shock. Make sure
the power has been disconnected before
performing the following procedures. Refer to
Important Safety Instructions located on page 2.
CAUTION: Risk of electrical shock. All services
must
have
a
Circuit-Interrupter (GFCI) which will provide
additional protection against line-to-ground shock
hazard.
A licensed electrician should make a routine service
connection to the field wiring compartment of the pump
containing black and white wires and ground screw.
NOTE: The electrician must supply a listed strain/relief
bushing in accordance with local codes.
Remove air actuator tubing from pump by gently pulling.
Next, remove the screw at the top of the pump near the
strain relief bushing. Save screw. Loosen screw at
bottom of pump. Remove pump cover to reveal field
wiring compartment.
* For bonding in accordance with National and Local
Codes.
D. FIELD WIRING DIAGRAM - 120 V, 60 HZ (-J1
MODELS ONLY)
The factory has prewired the whirlpool control system.
A 120 V, 15 A separate circuit is required. Provide a
separate equipment grounding conductor for the inside
grounding conductor for the inside grounding screw (14
AWG minimum). Ground must not be connected to any
current-carrying conductor except at the main service
breaker box (per National Electrical Code, Article
250-61-b).
Replace pump cover over field wiring compartment.
Fasten screw through cover at hole near strain relief at
top of pump. Tighten screw at bottom of pump. Snip off
approximately 1" of air actuator tubing and reattach to
pump. Make sure tubing is securely attached to pump.
CA
106548-
(9437)
Class
A
Ground-Fault
Air
Actuator
Air
Actuator
Tubing
Green (Ground)
Black (Line)
To Electrician: Pro-
vide enough wire to
allow motor removal
upon servicing.
Strain Relief Bushing
(Not Provided)
18
Field Wiring
Compartment
Bonding
(Earthing)
Screw*
Pump
White
(Neutral)
Air Actuator Tubing
Connection
Kohler Co., Kohler WI