Height Adjustment; Secure Whirlpool; Install Plumbing - Kohler K-1200-AC Installation Instructions Manual

Builder portfolio whirlpool baths
Table of Contents

Advertisement

B. HEIGHT ADJUSTMENT
NOTICE: Steps B. and C. are necessary for making
your Kohler Whirlpool operate more quietly.
If the subfloor is level, no adjustment is necessary;
proceed to Step C. If the subfloor is not level, shim
beneath pump bracket (plywood is recommended). Do
not change the elevation of the pump relative to the
whirlpool bath since this may affect performance. Use
a 5 x 7 (minimum) piece of plywood.
C. SECURE WHIRLPOOL
Using four 1/4" x 1" lag screws, secure pump bracket to
subfloor. Predrilling is recommended.
CAUTION: Risk of product damage. Do not
use the piping or pump for structural support or
positioning of whirlpools.
Use a 1/2" wrench to remove the long bolt securing the
bracket to the bath.
D. INSTALL PLUMBING
CAUTION: Risk of damage to whirlpool
bottom and subfloor. Ensure watertight seal on
bath drain connections.
1.
When whirlpool is securely positioned, connect
drain into trap. An access panel will simplify future
maintenance.
2.
Install the faucet valving and spout tee. If faucets
are deck-mounted, the deck must be finished
before handle trim and spout can be installed. Open
hot and cold valves and check all supply
connections for leaks.
3.
Run water in whirlpool and check drain connection
for leaks.
CA
106548-
(9437)
É É
Spacer
Plywood
(if required)
É
Lag Screw
16
Drainage
É É
Shim if necessary, using 5" x 7"
(minimum) plywood
Bracket
Bolt
Connect Here
Kohler Co., Kohler WI

Advertisement

Table of Contents