To configure TCP/IP rules, select TCP/IP Filter Rule from the Filter Type field and press [ENTER] to
open Menu 21.1.1.1 - TCP/IP Filter Rule, as shown next.
The following table describes how to configure your TCP/IP filter rule.
FIELD
Active
IP Protocol
IP Source Route
Destination
IP Address
Filter Configuration
Menu 21.1.1.1 - TCP/IP Filter Rule
Filter #: 1,1
Filter Type= TCP/IP Filter Rule
Active= Yes
IP Protocol= 0
Destination: IP Addr= 0.0.0.0
IP Mask= 0.0.0.0
Port #= 137
Port # Comp= Equal
Source: IP Addr= 0.0.0.0
IP Mask= 0.0.0.0
Port #=
Port # Comp= None
TCP Estab= N/A
More= No
Action Matched= Check Next Rule
Action Not Matched= Check Next Rule
Press ENTER to Confirm or ESC to Cancel:

Figure 23-6 Menu 21.1.1.1 TCP/IP Filter Rule

Table 23-3 TCP/IP Filter Rule

Press [SPACE BAR] and then [ENTER] to select Yes to
activate the filter rule or No to deactivate it.
Protocol refers to the upper layer protocol, e.g., TCP is 6, UDP
is 17 and ICMP is 1. Type a value between 0 and 255. A value
of 0 matches ANY protocol.
Press [SPACE BAR] and then [ENTER] to select Yes to apply
the rule to packets with an IP source route option. Otherwise
the packets must not have a source route option. The majority
of IP packets do not have source route.
Enter the destination IP Address of the packet you wish to
filter. This field is ignored if it is 0.0.0.0.
IP Source Route= No
Log= None
DESCRIPTION
Prestige 324 User's Guide
OPTIONS
Yes
No
0-255
Yes
No
0.0.0.0
23-7