ICP-CC488 | User's Guide | 18.
18. Remote Arming by
Telephone
Arm your system from any remote location using the
telephone. For security reasons, the system cannot be
disarmed using this method. This feature requires a
touch-tone telephone. Your installer must program
this feature to operate.
How to Remotely Arm Your System by Telephone
1. Call the telephone number connected to your
control panel.
2. When the control panel answers the incoming
call, a short jingle sounds. To arm the system,
press the [*] key on the touch-tone telephone for
1 sec to 3 sec.
If you hear modem tones when the control panel
answers the incoming call, the system was
programmed for remote programming functions
by your installer. Wait for a pause between the
tones before pressing the [*] key.
After releasing the [*] key on the touch-tone
telephone, two beeps sound, indicating that the
system is armed in AWAY Mode.
3. Hang up the telephone and the system remains
armed.
If your installer programmed answering
machine bypass, call the control panel
twice to make a connection with the
system. For example, call the telephone
number your control panel is connected
to and let the call ring no more than four
times. Hang up the telephone. Wait a
minimum of 8 sec before you calling the
control panel again.

19. Partitioning

This feature only applies to the ICP-CC488 Control
Panels. Your control panel can be partitioned into
four individual areas. Each area can be operated
from one Master Partitioned codepad, or from
separate Area Addressable codepads.
19.1
Master Partitioned Codepad
Indicators
The indicators on a Master Partitioned codepad are
configured into four groups (such as Zone Indicators,
Area On/Off Display, Area Display, and Status
Indicators).
Bosch Security Systems, Inc. | 12/08 | F01U089456-02

Remote Arming by Telephone

Figure 8:
19.1.1
Zone indicators 1 to 8 show the status of each zone.
These zones belong to the area that has the Area
Display indicator lit. For example, if an indicator is
lit, that zone is unsealed. If the indicator is dark, that
zone is sealed.
19.1.2
The group of four Area On/Off indicators display
the status of each area. For example, if an indicator is
lit, that area is armed. If the indicator dark, that area
is disarmed.
19.1.3
The group of four AREA DISPLAY indicators show
which area the zones displayed belong to.
19.1.4
A group of four indicators display the following:
AUX Indicator
Displays when the control panel is using the
telephone line communicating to the receiving party.
MAINS Indicator
Displays the status of the AC MAINS power. (For
example, if the indicator is illuminated, the AC
MAINS power supply is normal. If the indicator is
flashing, the AC MAINS power supply is
disconnected or failed.)
FAULT Indicator
Displays the status of the fault register. (For example,
if the FAULT indicator is flashing, the system
detected a fault that is not yet acknowledged. If the
FAULT indicator is illuminated, the fault is
acknowledged. If the FAULT indicator is not
illuminated, the system has no faults.)
ICP-CP500PW Master Partitioned
Codepad

Zone Indicators

Area On/Off Indicators

Only Area 1 and Area 2 can be used with
the ICP-CC488 Control Panel.

Area Display Indicators

Status Indicators

EN | 16