Entry Guard Timer for STAY Mode 2
When arming the system in STAY Mode 2, an
optional entry timer called Entry Guard Timer for
STAY Mode 2 is available. Use this entry timer to
delay the sirens if a zone is not automatically isolated
and activated into alarm condition. Entry Guard
Timer for STAY Mode 2 is the delay time used for
all zones except 24-hour zones when the system is
armed in STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer for STAY Mode 2 is
programmed and a zone that was not automatically
isolated activates, the codepad beeps twice a sec until
the entry timer expires or the system is disarmed. If
the alarm condition is not reset by entering your user
code followed by the [#] button (for example,
[2580#]) before the entry timer expires, the sirens
activate into alarm. Only your installer can program
this option.
How to Arm the System in STAY Mode 2
Hold down the [0] button until two beeps sound.
The STAY indicator displays and Exit Time starts
counting.
Any zones programmed to be automatically isolated
in STAY Mode 2 flash until Exit Time expires. At
the end of Exit Time, all zones selected to be
automatically isolated extinguish and the codepad
emits one short beep.
3.10.5

Programming STAY Mode 2 Zones

Programming zones to be automatically isolated in
STAY Mode 2 are only carried out if you have a
Master Code.
How to Program STAY Mode 2 Zones
1. Enter your four character Master Code, followed
by [4] and the [#] button (for example,
[25804#]). Three beeps sound and the STAY
indicator flashes.
2. Enter the zone number to be automatically
isolated, followed by the [*] button (for example,
[1*] = Zone 1, [2*] = Zone 2).
The selected zone flashes. If you make a mistake,
enter the same zone number followed by the [#]
button to clear the incorrect zone.
To select additional zones to be automatically
isolated in STAY Mode 2, repeat Step 2 as many
times as required.
3. Press the [#] button to exit this mode when you
finish selecting all zones to be automatically
isolated in STAY Mode 2. Two beeps sound and
the STAY and AWAY indicators turn off.
Bosch Security Systems, Inc. | 12/08 | F01U089456-02

Disarming the System

4.
When you enter the premises after the system is
armed in AWAY mode, or if you armed the system
in STAY Mode 1 or STAY Mode 2, you must disarm
the system to disable detection devices that activate
an alarm.
If there was an alarm condition prior to disarming
the system, a flashing zone indicator displays,
indicating a previous alarm on that zone.
How to Disarm the System
Enter your user code followed by the [#] button (for
example, [2580#]). Two beeps sound.
5.
5.1
Only the Master Code holder can add or change
other system user codes, including the Master Code.
Up to eight user codes can be programmed to
operate the system.
How to Add a User Code
1. Enter your four character Master Code, followed
by [1] and the [#] button (for example,
[25801#]).
Three beeps are heard and the STAY and
AWAY indicators flash.
2. Enter the User Code number (1 to 8), followed
by the [#] button (for example, [2#] = User 2,
[8#] = User 8). Two beeps are heard and the
selected user number displays on the codepad
indicators.
3. Enter the digits required for the new code
followed by the [#] button (for example, for User
Code 5768, enter [5768#]). Two beeps are heard
and the STAY and AWAY indicators turn off.
To add or change other User Codes, repeat this
procedure as many times as required.
5.2
Only the Master Code holder can add or change
other system user codes. Up to eight radio user codes
(User Codes 9 to 16) can be programmed to operate
the system.
How to Add a Radio Remote User Code
1. Enter your four character Master Code, followed
by [1] and the [#] button (for example,
[25801#]).
Three beeps sound and the STAY and AWAY
indicators flash.
2. Enter the radio remote user code number (9 to
16), followed by the [#] button (for example,
[9#] = User 9, [16#] = User 16). Two beeps are
heard and the selected user number displays on
the codepad indicators.
Disarming the System

User Codes