Configuring Optional Parameters For An Nqa Test Group - HP 6125G Configuration Manual

Network management and monitoring configuration guide
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Step
1.
Enter system view.
2.
Enter NQA test group
view.
3.
Enter NQA test type view.
4.
Enable the saving of the
history records of the
NQA test group.
5.
Set the lifetime of the
history records in an NQA
test group.
6.
Configure the maximum
number of history records
that can be saved for a test
group.
Configuring optional parameters for an NQA test
group
Optional parameters for an NQA test group are valid only for tests in this test group.
Unless otherwise specified, the following optional parameters are applicable to all test types.
To configure optional parameters for an NQA test group:
Step
1.
Enter system view.
2.
Enter NQA test group view.
3.
Enter test type view of a test
group.
4.
Configure the description for a
test group.
Command
system-view
nqa entry admin-name
operation-tag
type { dhcp | dlsw | dns | ftp
| http | icmp-echo | snmp |
tcp | udp-echo | udp-jitter |
voice }
history-record enable
history-record keep-time
keep-time
history-record number
number
Command
system-view
nqa entry admin-name
operation-tag
type { dhcp | dlsw | dns
| ftp | http | icmp-echo
| snmp | tcp | udp-echo
| udp-jitter | voice }
description text
116
Remarks
N/A
N/A
N/A
By default, history records of the NQA test
group are not saved.
Optional.
By default, the history records in the NQA
test group are kept for 120 minutes.
Optional.
By default, the maximum number of records
that can be saved for a test group is 50.
Remarks
N/A
N/A
N/A
Optional.
By default, no description is available for a
test group.

Advertisement

Table of Contents
loading

This manual is also suitable for:

6125 blade switch series

Table of Contents