The output shows that GigabitEthernet 1/0/1 enabled with sFlow is active, the counter sampling interval
is 120 seconds, the Flow sampling interval is 4000, all of which indicate sFlow operates normally.

Troubleshooting sFlow configuration

Symptom
The remote sFlow collector cannot receive sFlow packets.
Analysis
The sFlow collector has no IP address specified.
No interface is enabled with sFlow to sample data.
The IP address of the sFlow collector specified on the sFlow agent is different from that of the remote
sFlow collector.
No IP address is configured for the Layer 3 interface on the device, or the IP address is configured,
but the UDP packets with the IP address being the source cannot reach the sFlow collector.
The physical link between the device and the sFlow collector fails.
Solution
Check whether sFlow is correctly configured by displaying sFlow configuration with the display
1.
sflow command.
Check whether the correct IP address is configured for the device to communicate with the sFlow
2.
collector.
Check whether the physical link between the device and the sFlow collector is normal.
3.