4.6.6 Setting Up Judgement Criteria in JUDGEMENT CRITERIA and
MEASUREMENT OBJECT MIN. SETTING modes
Based on the base measurement saved by teaching, the allowable limits for OK judgement specified each in
X and Y direction in mm.
Operation in JUDGEMENT CRITERIA SETTING mode
In INSPECTION (or RUN) mode
92
In JUDGEMENT CRITERIA SETTING mode ("SET" is displayed.)
Referring the value saved during teaching
•
•
•
•
Allowable range to be set
•
•
•
•
•
•
MinX: Min. for Measurement Object - in the X
direction
•
•
MinY: Min. for Measurement Object - in the Y
direction
•
•
RMinX: Min. in the X direction
RMaxX: Max. in the X direction
RMinY: Min. in the Y direction
RMaxY: Max. in the Y direction
PMinX: Min. in the X direction
PMaxX: Max. in the X direction
PMinY: Min. in the Y direction
PMaxY: Max. in the Y direction
The <8> button: Increases the value
The <7> button: Decreases the value
The <8> button: Increases the value
The <7> button: Decreases the value
The <8> button: Increases the value
The <7> button: Decreases the value