TEACH: OKNG (teaching for OK and NG products)
In INSPECTION (or RUN)
mode
If you change to RUN mode before teaching for NG product, the ALARM signal is output. The
ALARM signal is held ON until teaching for OK and NG products are successfully completed. As
long as the unit keeps outputting the ALARM signal, it cannot execute an inspection properly.
90
TEACHING mode ("TEACH" is displayed.)
Upper line- Binary level: 0 – 255
(default: 150)
<3>: Decreases the value
<4>: Increases the value
Lower line-Exposure time: 0.03
to 50.00 ms (default: 1.93)
<7>: Shortens the
exposure time
<8>: Extends the exposure
time
If you want to perform a teaching
at this point, press <6> first and
then <1>.
SIZE: Resizes the inspection
area
If you want to execute a teaching
at this point, press the <6> first
and then <1> after resizing.
MOVE: Moves inspection area
<6>: Executes a teaching for
the current product type
Executes a teaching for OK
product of the current product
type.
STNG: Teaching for OK
products-Normal completion
FAIL:Abnormal termination of
teaching
(The ALARM signal is output.)
<6>: Executes a teaching
Executes a teaching for NG
product of the current product
type
DONE: Teaching for NG
product-Normal completion
FAIL: Failed to complete
teaching (The ALARM signal is
output.)
<5>: Returns to the top.
You can always switch
the product types by
pressing <2> and <5>
buttons at the same
time.