4.6.2 Setting Procedure and Modes

Make the inspection settings following the steps below:
1
Set up devices
2
Turn the LightPixAE20 on.
Configure the
LightPixAE20.
3
(in CONFIGURATION mode)
The minimum value for
inspection object
4
(In JUDGEMENT CRITERIA
SETTING)
Run a teaching
5
(In TEACHING mode)
Set judgement criteria
6
JUDGEMENT CRITERIA
SETTING mode)
Execute an inspection
7
(in RUN / RUNVIEW mode)
There are mainly four modes available for the LightPixAE20. The settings that you can make vary depending
on the mode. To switch the modes, follow the instructions below.
84
Install the main unit, and connect to a power supply unit,
each unit and external devices
Apply 24 V DC.
Set up the LightPixAE20 system in CONFIGURATION
mode. Hardware settings of the unit, output method of
reading data, saving method of captured images and other
inspection conditions.
In JUDGEMENT & INSPECTION MINUMUN VALUE
SETTING modes, set the minimum value for the inspection
object of which a length is measured. The unit detects only
the parts more than the minimum value for inspection object.
In the TEACHING mode, register edge direction and
distance, at the same time, set the exposure time or range
for measuring area (inspection area), and area for setting
extraction color.
In JUDGEMENT CRITERIA SETTING and INSPECTION
(In
MINUMUN VALUE SETTING mode, set the limits of area
values (min. and max.). and the threshold value of degree of
similarity for detected image.
Press the TRIGGER button in RUN (RUN VIEW) mode.