TEACH: OKNG (Teaching for OK product and NG product
In INSPECTION (or RUN)
mode
54
In TEACHING mode ("TEACH" is displayed)
TEMP: Saved template
The saved template image is
displayed at the left upper
area on the finder unit.
Exposure time: 0.03 to
50.00 ms (default: 1.93)
<7>: Shortens time
<8>: Extends time
SIZE: Resizes inspection
area
MOVE: Moves inspection
area
T.SIZE: Resize the color
extraction area
T.MOVE: Moves the color
extraction area
M.SIZE: Resizes the
template area size
M.MOVE: Moves template
area
Upper line: The degree of similarity for
the previous teaching "0" is displayed when
executing a teaching for the first time.
Lower line: M85 - the threshold value for
degree of similarity
<6>: Executes a teaching
Teaching is executed for the current product
type.
ADJ: Teaching is being executed
STNG: Teaching for OK product –
Successful teaching
FAIL: Teaching failure (ALARM signal is
output.
<6> Teaching Execution
Executes a teaching for NG product of the
current product type
Values (two digits): The degree of
similarity detected during a test run
When the unit competes a teaching, the
degree of similarity appears in the ADJ
display area.
<5>: Returns to the top.
NO TEMP:
If no template
is saved
If you want
Product type
switch
to perform a
teaching at
Press the <2>
any point,
button and the
press <6>
<5> button at the
and then
time to change the
<1>.
product types.
But, after
executing a
teaching for OK
product, product
type switch is
unavailable before
teaching for NG
product.
Display of
teaching
completion
Execute a
teaching If
teaching is
successfully
completed by the
time of inspection
area move,
"DONE" is
displayed a the
upper line
Example: