4.3.6 Inspection Execution

The Ways of inspection execution
Internal trigger: ON
Internal trigger: OFF
Inspection judgement results
Output judgement results to the parallel ports of OUT1 to OUT3 as the table shown below.
Judgement results
All OK
An image having more than the specified
degree of similarity is detected.
X- and Y- positions (distance) is within the
allowable range.
Image
An image having more than the specified
Detection
degree of similarity is detected
X = OK
X-position (distance): Within the limit
Y-position (distance): Out of the limit
Image
An image having more than the specified
Detection
degree of similarity is detected.
Y = OK
X-position (distance): Out of the limit
Y-position (distance): Out of the limit
Image
An image having more than the specified
Detection
degree of similarity is detected, but X- and
Y-position (distance) is out of range
Any images having more than the specified degree of
similarity are not detected.
Switch the internal trigger signal (I.TRR) ON/OFF in CONFIGURATION mode.
Parallel input/output timing chart: Page 102
Inspection is automatically performed by switching to RUN mode.
After switching to RUN mode, input the TRIGGER signal via the external device or
press the TRIGGER button.
OUT3
OUT2
OUT1
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF