3.4.5 Grounding the Main Unit

Observe the followings to connect the grounding cable.
Do not commonly use the ground with other devices.
Grounding should be as close as the main unit as possible, and keep the distance short.
Use a grounding cable of 0.5 to 1.25mm2 diameter.

3.4.6 Comformity to the EMC standard

The LightPixAE20 will comply with the EMC standards (EN61000-6-4, EN61000-6-2) in EMC Directive (EMC
Directive 89/336/EEC). The product must fulfill the following conditions:
1. No USB communication
2. Ferrite core must be used for the wirings as the figures shown below.
3. Mounting plate ANE8870 (separately sold) must be used for grounding.
Mount Plate - Product No. ANE8870
Manufacturer
Ferrite Core
TDK CO., LTD.
Product No.
ZCAT1730-0730A