Edge Detection - Panasonic LightPix AE20 User Manual

Table of Contents

Advertisement

6.4.3 Edge Detection

Type of
Item
item
INSPECTION
Detection
Edge
Direction
Judgement
Results
Measurem
ent Time
Detection
Edge
Position
(mm)
Product
Type
Inspection
Start
READY
ALARM
LOCK
Mode
OUT1
OUT2
OUT3
TEACHING
Exposure
Time
Setting
Setting of
inspection
area
122
Data
Setting
Com-
register
value
mand
No.
range
RD
1100
0-3
RD
1102
0/1
RD
1103
---
RD
1104-1105 Depends
on the
type of
unit
RD/WD 1400
1-7
WD
1500
1
RD
1600
0/1
RD
1601
0/1
RD/WD 1602
0/1
RD/WD 1603
0-4
RD
1604
0/1
RD
1605
0/1
RD
1606
0/1
RD/WD
2100
0003
-5000
2101
2102
2103
2104
2105
2106
RD/WD
2200
X:351-0
Y:287-0
2201
2202
2203
2204 -2207
2208 -2211
2212 -2215
2216 -2219
2220 -2223
2224 -2227
Remarks
0/1: X
2/3: Y
1: OK
0: NG
Measurement time
Actual values and double-word type
The position of a detected edge (mm)
WD: Switches the product types
RD: Reads the current product type
Start an inspection
1: ON
0: OFF
0: RUN mode
1: RUN/VIEW mode
2: TEACH mode
3: CONFIGURATION mode support for RD
4: JUDGEMENT CRITERIA SETTING mode (support
for RD)
1: ON
0: OFF
Product Type 1
WD:
Used for running a teaching in data
Product Type 2
area 2500 using "1" (without
Product Type 3
exposure time adjustment).
Product Type 4
RD:
Product Type 5
Reads the current exposure time
Product Type 6
Product Type 7
Product Type 1: X coordinate at upper left
Product Type 1: Y coordinate at upper left
Product Type 1: X coordinate at lower right
Product Type 1: Y coordinate at lower right
Product type 2: X coordinate at upper left - Y
coordinate at lower right
Product type 3: X coordinate at upper left - Y
coordinate at lower right
Product type 4: X coordinate at upper left - Y
coordinate at lower left
Product type 5: X coordinate at upper left - Y
coordinate at lower right
Product type 6: X coordinate at upper left - Y
coordinate at lower right
Product type 7: X coordinate at upper left - Y
coordinate at lower right

Advertisement

Table of Contents
loading

Table of Contents