Operation in TEACHING mode
The teaching procedure differs between for OK product only and for OK/NG
products. (Type of teaching is selectable in CONFGURATION mode.)
The number in < > in the table below represents the button number of the o
unit (see the figure on the right).
TEACH: OK (teaching for OK product only)
In INSPECTION (or RUN)
mode
If you change to RUN mode before teaching for NG product, the ALARM signal is output. The
ALARM signal is held ON until teaching for OK and NG products are successfully completed. As
long as the unit keeps outputting the ALARM signal, it cannot execute an inspection properly.
TEACHING mode ("TEACH" is displayed.)
Upper line- Binary level: 0 – 255
(default: 150)
<3>: Decreases the value
<4>: Increases the value
Lower line-Exposure time: 0.03
to 50.00 ms (default: 1.93)
<7>: Shortens the exposure time
<8>: Extends the exposure time
If you want to perform a teaching
at this point, press <6> first and
then <1>.
SIZE: Resizes the inspection
If you want to execute a teaching
at this point, press <6> first and
then <1> after resizing.
MOVE: Moves inspection area
<6>: Executes a teaching for
the current product type
Teaching for the current product
type is executed.
DONE: Indicates successful
completion of teaching
FAIL: Abnormal termination of
teaching
(The ALARM signal is output.)
<5>: Returns to the top.
peration
You can always switch
the product types by
pressing the <2> and
<5> buttons at the
same time.