Update process

It is advisable to perform a couple of checks before carrying out the software update process.
Check that there are no warnings or errors reported on any of the hardware.
If there are messages in here, please rectify them.
If the page is blank, this means that all hardware is reported as good.
The actual upgrade process requires you to:
1.
sftp the package to the staging area
2.
Run the StoreOnce CLI software update commands
3.
Check that the update has completed successfully
Please refer to the release notes accompanying the software update or to the HP StoreOnce Backup
system Maintenance and Service Guide for step-by-step instructions.
sftp the package to the staging area
sftp the package (D2D_Master <revision_info>.rpm) to the staging area of the active
node.
Using Linux
sftp Admin@<IP_address>
cd repository (the full path is /jail/repository)
put D2D_Master <revision_info>.rpm
exit sftp
Using a Windows sftp client
Ensure the File Protocol is set to SFTP, not SCP.
Login as Admin.
Copy D2D_Master <revision_info>.rfm to repository.
Run the StoreOnce CLI software update commands
Enter the following StoreOnce CLI commands:
system show repository which should list out the rpm file you copied over
system load package D2D_Master <revision_info>.rfm which will distribute the
package and unpack it (into/stage/packages)
system show packages which will show you the packages staged ready for update
system update packages which will begin the process to upgrade and reboot the system
After the reboot
Wait for the reboots to occur.
NOTE:
Depending upon the updates, this could take 30 minutes or longer. If you do not have a
console connected, you will not have any feedback reported over the Management Console during
this time.